60
Frequency (Hz)
Minimum Linear
Level (dB)
Linear Dynamic
Range (dB)
Noise Floor (dB)
132.5 33.5 99.0
132.5 34.1 98.4
132.5 35.8 96.7
132.5 37.1 95.4
1/3 Octave Filter Summation
For this test, sine waves from 20 Hz to 20 kHz are measured with the Concerto system. For each sine
wave the summation of the 1/3 octave filters is computed to form the following curves. The sine
waves are electrical signals at 1 VRMS. The next figures present the results for both input range.
Summation Test (Low Range Case)
-0.5
-0.4
-0.3
-0.2
-0.1
0
0.1
0.2
0.3
0.4
0.5
10
100 1000 10000 100000